Bird SH-42S-TC Signal Hawk

 

 

 

Vicom - Contact Us

  Bird SignalHawk Data Sheet Bird SH-42S Manual 
  Data Sheet Operation Manual


The Signal Hawk SH-42S-TC is highly portable unit, easy to use and the intuitive menus to simplify operation
for the occasional or seasoned user

Need to equip your workforce
• Priced so that you can buy one of these for each of your technicians. 
Need faster sweeps
• More than 2x faster sweep times than the competition.
Poor lighting or bright light
• High-resolution, full-color display for indoor or outdoor viewing.
Require Power Measurement
• Includes the Bird RF Meter App that allows interoperability with a wide range of Bird Field sensors.
Laptop requirement
• Work orders can be viewed right on the instrument with a .pdf/.doc viewer. Can upload custom user written WordPad
   help file. 
Lack of access to AC
• 10% longer battery life (6 hours per charge), with Lithium Ion battery.

 

Product Specifications

Item No         

 

 SH-42S-TC

Item Name

                                                                                                                                                                                           

Hand-Held Spectrum Analyzer

Frequency Range

 

 10 MHz - 4.2 GHz

Frequency Span Accuracy

 

±1% 

Sweep Time

 

 1.1ms ~ 1600s

Bandwidth Range

 

 10 Hz ~ 5 MHz

Bandwidth Accuracy

 

 ≥ 1 MHz, ±10%, <1 MHz, ±2%

Measurement Range                

 

 DANL to +20dBm

Input Attenuator Range               

 

 0~30dB, 1dB step

Max Safe Input Level Sensitivity                             

 

Preamp Off: +20 dBm

Preamp +20 dBm: 0 dBm 

Preamp +40 dB: -20 dBm  

Reference Level Range  

  -140 dBm to +20 dBm Ref Level Offset: ON, -190 dBm to +70 dBm

Amplitude Accuracy          

   ±1.5 dB (ATT set to 0 dB , input signal -5 to -30dBm, Detector set to Positive, Sensitivity set to Low, RBW auto-coupled, all other settings auto- coupled, 23±5 °C. Half hour warm-up required.) 

Switching Uncertainty                                         

   ±0.3dB

Input Attenuator

   ±0.6 dB

Level Accuracy

   ≥ -60 dBm, ±0.8 dB

Average Noise Level Sensitivity

  Low: 1 GHz, -131 dBm/Hz (Typ -133 dBm/Hz) 
Medium: 1 GHz, -151 dBm/Hz (Typ -153 dBm/Hz)
High: 1 GHz, -168 dBm/Hz (Typ -169 dBm/Hz) 

Residual Responses

  -75 dBm 

Input Related Responses

 

 

10 MHz - 1.285 GHz: -70 dBc
1.285 GHz - 1.625 GHz: -42 dBC
1.625 GHz - 1.775 GHz: -55 dBc
1.775 GHz - 2.35 GHz: -42 dBc
2.35 GHz - 2.71 GHz: -25 dBc
2.71 GHz - 3.22 GHz: -42 dBc
3.22 GHz - 3.7 GHz: -70 dBc
3.7 GHz - 4.2 GHz: -35 dBc

Second Harmonic                                              

 

1.6 GHz -70 dBc 

Third-Order Intercept                                      

 

 +15 dBm (–10 dBm tones ,1 MHz apart, Sensitivity                  

 LOW, Reference Level –10 dBm)

P1dB                                                                                     

 

+5 dBm Nominal 

Phase Noise 1 GHz

  -96 dBc/Hz,@10 kHz (typical -98 dBc/Hz)-118 dBc/Hz,@1 MHz (yypical -120 dBc/Hz)                                   

Connectors

 

RF In: N type, female 

USB: Type C Power Interface: Slim Tip, DC20 

Operating System

 

Android                             

Battery Operating Time

 

6 hours typical 

Battery Charging Time

 

2.5 hours typical  

Operating Temperature 

 

0°C to 50°C 

Storage Temperature

 

-20°C to 70°C 

Size

 

7.8 in x 3.9 in x 2.6 in, (200mm x 99mm x 67mm) 

Weight 

 

2.8 lb (1.25 kg)